TGem One is a high-sensitivity fluorometer designed for accurate quantification of DNA, RNA and protein samples, especially for low-concentration and rare samples where traditional spectrophotometers are not well suited for precise analysis.
Using fluorescence-based detection, TGem One provides superior specificity and sensitivity compared to UV absorbance methods, enabling reliable measurement of extremely low concentrations across multiple biomolecules. It is widely used in molecular biology workflows such as DNA, RNA and protein quantification, sample quality control and next-generation sequencing (NGS) library preparation.
With a minimum sample volume of 1 μl and rapid detection within seconds, TGem One reduces sample consumption while improving laboratory efficiency. Its intuitive 7-inch touchscreen interface and built-in functions, including standard curve calibration and reagent calculation, ensure simple operation and consistent results.
TGem One delivers high-sensitivity fluorescence quantification comparable to leading international fluorometers, providing a cost-effective and reliable solution for laboratories requiring precise analysis of DNA, RNA and protein samples.
-
Why Choose TGem One Fluorometer
High Sensitivity for Low-Concentration DNA, RNA and Protein Samples
Designed for fluorescence-based detection, TGem One enables accurate quantification of extremely low concentration DNA, RNA and protein samples, making it ideal for rare or valuable samples that cannot be reliably measured by traditional spectrophotometers.
More Reliable Than UV Absorbance Methods
Fluorescence detection provides higher specificity than traditional absorbance-based methods, reducing interference from contaminants such as proteins, salts and solvents, and improving overall data accuracy.
Minimal Sample Consumption (1 μL)
Requires only 1 μL of sample, helping conserve valuable samples while maintaining precise and reproducible results.
Fast Measurement within ≤5 Seconds
Delivers rapid measurement in ≤5 seconds, improving laboratory efficiency and enabling high-throughput workflows.
Cost-Effective Performance Comparable to Leading Fluorometers
Provides high-sensitivity fluorescence quantification comparable to leading international fluorometers, combining performance, usability and cost efficiency in one compact system.
User-Friendly 7-Inch Touchscreen Interface
Equipped with a 7-inch touchscreen and intuitive interface, enabling simple operation and faster workflow compared to traditional button-based systems.
Integrated Functions for Laboratory Efficiency
Built-in tools such as standard curve calibration, data storage and reagent calculation help streamline workflows and reduce manual errors.
-
Applications
High-Sensitivity DNA, RNA and Protein Quantification
Accurate quantification of DNA, RNA and protein samples for molecular biology workflows, including PCR, qPCR and sequencing preparation.
Low-Concentration Sample Analysis
Ideal for detecting low-abundance DNA, RNA and proteins where traditional spectrophotometers are not suitable.
NGS Library Preparation
Ensures precise nucleic acid quantification for next-generation sequencing workflows, improving data quality and sequencing reliability.
Fluorescence-Based Protein Quantification
Enables sensitive and reliable protein concentration measurement using fluorescence detection methods, especially for low-concentration samples.
Sample Quality Control Across Biomolecules
Used to evaluate the quality of DNA, RNA and protein samples and validate extraction or purification processes in laboratory workflows.
-
Key Features
High Sensitivity Detection for Low-Concentration DNA, RNA and Protein
Designed for fluorescence-based detection, TGem One enables accurate quantification of extremely low concentration DNA, RNA and protein samples, making it ideal for rare and low-abundance samples that cannot be reliably measured by traditional spectrophotometers.
Versatile Assay Support for Multiple Biomolecules
Supports fluorescence-based quantification of DNA, RNA and protein, enabling flexible and reliable analysis across a wide range of molecular biology workflows.
Minimal Sample Requirement (1 μL)
Requires as little as 1 μL of sample, helping preserve valuable samples while maintaining accurate quantification.
Fast Detection within ≤5 Seconds
Rapid measurement enables efficient workflows and quick decision-making in both routine and advanced laboratory applications.
User-Friendly 7-Inch Touchscreen
The large and responsive 7-inch touchscreen provides a clear interface and intuitive interaction, improving usability compared to traditional systems.
Integrated Data Management and Analysis
Built-in functions for data storage, standard curve analysis and result calculation simplify workflows and improve reproducibility.
-
Efficient Workflow and Data Management
Flexible Data Storage and Export
Supports storage of up to 10,000 samples with options for external USB storage. Data can be easily exported or printed, enabling efficient data management and documentation.
Convenient Data Output and Sharing
Results can be exported via USB or printed using external devices, simplifying data sharing and record keeping in laboratory workflows.
Built-In Calculation and Analysis Tools
Integrated tools for dilution calculation, concentration conversion and sample volume estimation help reduce manual steps and improve workflow accuracy.
-
Technical Specifications
Technical Specifications
Parameter TGem One Fluorometer Sample Types DNA / RNA / Protein Detection Method Fluorescence-based quantification (with reagents) Detection Limit 0.1 pg/μL Dynamic Range 5 orders of magnitude Minimum Sample Volume 1 μL Measurement Time ≤5 seconds Excitation Wavelength Blue 470±20 nm
Red 625±20 nmEmission Wavelength Green 525–570 nm
Red 670–725 nmDetector Photodiode Display 7-inch touchscreen Data Storage 10,000+ samples with USB support Interface USB (Type A ×2), USB (Type B ×1), LAN ×1 Sample Format 0.5 mL transparent tube Dimensions 286 × 161 × 61 mm Weight 1.5 kg Power Supply 100–240 V, 50–60 Hz -
FAQ
What is TGem One Fluorometer used for?
A: TGem One is used for high-sensitivity fluorescence quantification of DNA, RNA and protein, especially for low-concentration samples that cannot be accurately measured by spectrophotometers.
Why use a fluorometer instead of a spectrophotometer?
A: Fluorescence-based detection provides higher specificity and sensitivity, especially for low-abundance samples, by reducing interference from contaminants such as proteins, salts and solvents.
What is the detection limit of TGem One?
A: TGem One can detect samples down to 0.1 pg/μL, making it suitable for low-concentration DNA, RNA and protein samples.
How much sample volume is required?
A: Only 1 μL of sample is required, helping conserve valuable samples while maintaining accurate measurement.
How fast can the fluorometer measure samples?
A: Each measurement can be completed within ≤5 seconds, enabling efficient processing of multiple samples.
What types of samples can be measured?
A: TGem One supports quantification of DNA, RNA and protein using fluorescence-based detection reagents.
Is it suitable for low-concentration DNA, RNA and protein samples?
A: Yes, it is specifically designed for low-concentration and low-abundance samples where traditional absorbance-based methods are not reliable.
Does it support data storage and export?
A: Yes, the system supports storage of up to 10,000 samples and allows data export via USB or external devices.
Is it easy to operate?
A: Yes, it features a 7-inch touchscreen interface and built-in calculation functions, making operation simple and efficient.
How does TGem One compare to other fluorometers?
A: TGem One provides high-sensitivity fluorescence quantification comparable to leading fluorometers, while offering a more intuitive interface, faster workflow and improved cost-effectiveness.
-
Sort by
-
Date
Date(
)
Date
Date(
)
Impact Factor
IF(
)
Impact Factor
IF(
)

Inquire