Features
● All-in-one rotor, no need to replace the rotor when using centrifuge tubes with different volumes.
● Mute technology ensures low noise.
● The bottom weighting design ensures no displacement.
● Durable, safe and reliable.
● Powerful high speed: The 8,000 rpm high speed motor and larger centrifugal angle speed can achieve fast centrifugation.
● Suffcient space, which makes it convienient to put and take out centrifuge tubes.
-
Description
TGear Mini Centrifuge is a mini short-spin centrifuge suitable for various types of centrifuge tubes. It is suitable for the centrifugation before PCR experiment, and other molecular biological experiments such as rapid sample precipitation, separation of supernatant from various samples, separation of serum from whole blood as well as the separation of blood cells of trace amount.
-
Parameters
-
Precautions
Please do not:
● Operate the centrifuge in any way other than the instructions provided in the manual.
● Add solution when the centrifuge tube is on the rotor.
● Put your hand in the rotor area before the rotor stops completely.
● Take out the centrifuge tube while the rotor is still rotating.
● Handle solution or infammable substances near any electrical instrument.
● Centrifuge infammable, explosive or corrosive substances.
● Centrifuge hazardous substances without wearing protective equipment.
Please ensure to:
● Load the rotor symmetrically to keep it in balance.
● Place the centrifuge near the socket.
● Use plastic centrifuge tubes that can bear at least 2,000 ×g of centrifugal force.
-
Quality Assurance
The warranty period of the TGear Mini Centrifuge is 12 months. Damage caused by improper operation or unauthorized modification with accessories or spare parts not provided by TIANGEN is not covered by the warranty. The warranty does not cover damage caused by normal spoilage, radioactive contamination or improper cleaning. Damage to the fuse wire is not covered by warranty. -
Important Notes
● Please use centrifuge tubes of the same specification and containing the same volume of liquid to assure the balance before running the instrument.
● Do not touch the rotor or move the machine until the rotor has completely stopped.
● The machine should be placed on a horizontal and sturdy workbench.
-
Maintenance and Service
The correct cleaning method provided in the operation manual will not cause damage to the instrument. Please read the manual carefully before performing the recommended cleaning methods. Clean the centrifuge with a wet cloth and a mild, non corrosive (pH < 8) detergent. After cleaning, please make sure that all parts of the centrifuge have been dried before use. Do not immerse the centrifuge in liquid or pour liquid on the device.
-