Features
● Simple operation: Simply load the microplate vertically from the slot at the top of the centrifuge.
● Wide application: Applicable to various standard PCR microplates with and without skirts, and can also be used in conjunction with the unique 8-tube strip fixing device of TIANGEN, which can centrifuge several 8-tube strips simultaneously.
● Strong power: The brushless motor can accelerate to 2,800 rpm instantaneously to ensure effective centrifuging and mixing of the wall hanging droplets to the bottom of the tube.
● User friendly: Two operation modes of instanteous and timing are configured to make the experiment more convenient and effcient. The cover can be opened to 95° angle to facilitate access to and placement of microplates.
● Quiet, stable and low noise: Noise is less than 75 decibels, providing a comfortable laboratory environment.
● Unique design, small in size.
-
Description
TGear Plate Centrifuge is a mini short-spin centrifuge specially designed for 8-tube strip/96-well plate/384-well plate. The liquid drops hanging on the side wall of the micro-well plates can be centrifuged instantly and the liquid can be mixed evenly. The product design relies on the principle that small amount of liquid can remain on the of the bottom of the micro-well plate by surface tense, so as to avoid the leakage of liquid from the plate after centrifugation.
-
Applications
TGear Plate Centrifuge can be widely used for the pulse-spin of the PCR/qPCR samples. -
Parameters
-
Precautions
● When reaching the maximum speed, the instrument may have slight vibration. Large vibration indicates the load on both sides of the rotor is unbalanced, and the operation of the instrument should be stopped. Please use the microwell plates with the same brand, specification and capacity of liquid, and run the instrument after balancing.
● It is forbidden to touch the rotor or move the instrument before the rotor is completely stopped.
● It is forbidden to centrifuge flammable, explosive or corrosive objects.
● It is forbidden to use unsealed microwell plates to avoid liquid leaking into the instrument.
● Please ensure that the microwell plate seal faces the middle of the rotor and the plate bottom faces the outside of the rotor.
● Before running this instrument, please make sure that the microwell plate is completely pushed to the bottom of the rotatory slot.
● This instrument should be placed on a level and stable working platform.
-
Quality Assurance
The warranty period of TGear Plate Centrifuge of our company is 12 months. Damage caused by improper operation or unauthorized modification by using spare parts or accessories not provided by TIANGEN is not covered by the warranty. The warranty does not cover the damage caused by normal wear and tear, radioactive contaminated instruments or improper cleaning. -
Important Notes
● Please ensure that the sealing surface of the microplate faces the middle of the rotor and the bottom of the plate faces the outside of the rotor.
● Please use microplates with the same brand, specification and containing same volume of liquid to confirm the balance before running the machine.
● Do not touch the rotor or move the instrument until the rotor is completely stopped.
● Do not apply unsealed microplates, or it will risk liquid leaking.
● The machine should be placed on a horizontal and sturdy workbench.
-
Schematic Diagram of Instrument
-
Appearance (Back)
-
Operation Panel
-
Operation Key Description
-
Maintenance and Service
Before maintenance and service, please ensure that the instrument is powered off and disconnect the power line. Customers are advised to wipe the instrument surface with 75% industrial alcohol or non-corrosive cleaning solution with pH = 7. Please ensure that all parts of the instrument are completely dry before running the instrument, and be careful not to immerse the instrument in liquid or wet the instrument with liquid.
-